Hight-temperature thermal insulation fibre

High-temperature thermal insulation fibre is used as thermal insulation for boilers, stress-relief welds, pipeline networks, glass-melting furnace arches in the nuclear industry, gas and steam turbines, various operator process cabins on rolling mills, cabinets, assemblies, etc.; lining of bell-type furnaces, industrial kilns for drying and firing, chimneys, air ducts, smoke stacks, walls and arches of tunnel and ring kilns in the ceramic industry, covers of shaft furnaces, walls and arches of heating, thermal, annealing and hardening furnaces, covers of low-temperature stands for heating tundishes, covers of steel-teeming ladles, smelting furnaces, as a sealant for furnace doors, thermal barriers in the automotive industry; filler for expansion joints in masonry; and is also a thermal insulation layer in furnace units.
Hight-temperature thermal insulation fibre

Physical and chemical parameters

Parameter name

Indicator value for grades

Soluterm® (1100) Soluterm® (1300) Аltraterm® (1600)
Chemical composition, %:
                        Al2O3, within            
                        SiO2, within 
                        СаО, within 
                        MgO, within 
                        СаО+MgО, NLT
     

-

62-68
26-32
4-7
-


-
NLT 70
-
-
20

     

71-74

26-29
-
-
-

Classification temperature, °C, not exceeding 1100 1300 1600
Tensile strength, kPa, of rated density
                       64 kg/m3
                       96 kg/m3
                       128 kg/m3
     

30
50
70

 

-
50
70

 

-
70
80

Mass fraction of non-fibrous inclusions of 45 µm or more, %, NMT
 33
35 5
Residual changes in dimensions when heated for 24 hours, at a temperature, %, NLT 1100 °С
minus 3
1260 °С
minus 3,5
1400 °С
minus 1
Colour white white -
Thermal conductivity at average temperature, W/m⋅K:
                     400 °С
                     600 °С
                     800 °С
                    1000 °С
                    1200 °С
                    1400 °С

thermal conductivity
values 
are shown
in table 1

thermal conductivity
values
​​are shown
in table 2

     

0,09
0,16
0,22
0,28
0,36
0,45


Table 1. Thermal conductivity coefficient for the grage Soluterm® (1100) at average temperature.

Temperature, °C

64 kg/m3 96 kg/m3
128 kg/m3
200 W/(m⋅K) 0,06 0,05 0,05
400 W/(m⋅K) 0,11 0,09 0,08
600 W/(m⋅K) 0,17 0,13 0,12
800 W/(m⋅K) 0,28 0,20 0,17
1000 W/(m⋅K) 0,40 0,28 0,25


Table 2. Thermal conductivity coefficient for the grage Soluterm® (1300) at average temperature.
Temperature, °C 96 kg/m3 128 kg/m3
200 W/(m⋅K) 0,05 0,04
400 W/(m⋅K) 0,10 0,08
600 W/(m⋅K) 0,18 0,14
800 W/(m⋅K) 0,30 0,22
1000 W/(m⋅K) 0,46 0,33
1200 W/(m⋅K) 0,68 0,46


Regulatory documentation: STO 05802307-1-008-2023


The maximum deviations in roll sizes depending on the rated density of 64 kg/m3, 96 kg/m3, 128 kg/m3 shall correspond to the values ​​specified in the table.




Roll dimensions and maximum deviations
Rated density, kg/m3 Length, mm Width, mm Rated thickness, mm Thickness specification Tolerance, mm Thickness variation, mm
min max min max
96 18500 610 6 6 10 0 4 3
128 18500 610 6 6 10 0 4 3
64 14640 610 13 13 17 0 4 3
96 14640 610 13 12 16 minus 1 3 3
128 14640 610 13 12 16 minus 1 3 3
64 9760 610 19 19 24 0 5 3
96 9760 610 19 17 22 minus 2 5 3
128 9760 610 19 17 22 minus 2 5 3
64 7320 610 25 25 30 0 5 3
96 7320 610 25 21 29 minus 2 4 3
128 7320 610 25 21 29 minus 2 4 3
64 4880 610 38 38 44 0 6 4
96 4880 610 38 35 42 minus 3 4 4
128 4880 610 38 35 42 minus 3 4 4
64 3660 610 50 50 58 0 8 5
96 3660 610 50 47 54 minus 3 4 5
128 3660 610 50 47 54 minus 3 4 5

Contact us

How to order

To place an order for the product supply, please do the following:
  1. On your company's letterhead, fill out an application, which shall include:
    • name of the requested product (or technical specifications thereof),
    • required amount,
    • estimated delivery time,
    • contact details.
  2. When ordering non-standard products (according to drawings), please attach the drawings of the requested product and indicate the dimensional tolerances.
  3. The completed application and drawings can be sent:
    • by email: tdom@slsoz.ru
    • by fax: (34373) 64 3 42; 64 4 63
    • or use the feedback form on the right

Write us

Contact us with any questions or place an order using the form. To place an order for the product supply, please do the following:

1. On your company's letterhead, fill out an application, which shall include:

    •  name of the requested product (or technical specifications thereof)

    •  required amount

    •  estimated delivery time

    •  contact details. 

2. When ordering non-standard products (according to drawings), please attach the drawings of the requested product and indicate the dimensional tolerances.